In Reply to: RE: I have already tried the cLC and hybrid options posted by DAK on August 30, 2017 at 09:31:08
Wire the "extra" 5 V. winding in series with the primary and measure. One configuration raises the rectifier winding's voltage, while the 2nd configuration lowers said voltage. You want the reduced voltage configuration.
Eli D.
Follow Ups:
If the primary is 1, 2 and the 5v is 3, 4 . I connect 1 and 3 and 2 and 4 and measure the B+ at the secondary. If that is not lower than without the 5v winding connected then i reverse the order of the connections?
Wire in series, not in parallel. Try 2 to 3 and apply "120" VAC to 1 and 4. If the rectifier winding measures higher, connect 2 to 4 and apply the mains voltage to 1 and 3.