In Reply to: RE: I have already tried the cLC and hybrid options posted by Eli Duttman on August 30, 2017 at 14:55:20
If the primary is 1, 2 and the 5v is 3, 4 . I connect 1 and 3 and 2 and 4 and measure the B+ at the secondary. If that is not lower than without the 5v winding connected then i reverse the order of the connections?
Follow Ups:
Wire in series, not in parallel. Try 2 to 3 and apply "120" VAC to 1 and 4. If the rectifier winding measures higher, connect 2 to 4 and apply the mains voltage to 1 and 3.
Eli D.
.