Audio Asylum Thread Printer Get a view of an entire thread on one page |
For Sale Ads |
24.63.247.173
In Reply to: RE: Zerozone PSU with wrong transformer? posted by tattenbach on December 04, 2019 at 10:45:27
OK, that's not what I was expecting to see. I was expecting to see the red and gray in series and the black and orange in connected to the EIC. Instead we have the red and gray connected to the EIC and we can't see the termination of the black and orange. I believe that if the black and orange are connected together the two transformer primaries are in series, but I wouldn't accept that as fact without checking it with my DVM first. Needs further study...
Follow Ups:
I agree the wiring based on the transformer label makes no sense. The primary connection (series or primary ) seems to be established in the transformer connection board. The wires running to the power switch should be switching the hot side of IEC though the connection board.
The black and orange are connected at the power switch. So it looks to me that the two primaries are connected in series.