KT88s draw more filament current than EL34s.

The difference is slight, 1.6 amps versus 1.5 amps, but if the power transformer supplies the tube filaments, this might be the source of your issue.

The self-bias circuit might also be causing the KT88s to draw more plate current. This would be worth checking. Perhaps the circuit is out of adjustment.

Most transformers have a small amount of mechanical hum under no- or light-load operation. The hum can get loud if the transformer gets close to maximum design load, or if there is enough harmonic distortion in the AC (the so-called 'DC on the AC' problem). Your comment that the transformer gets almost too hot to touch after a while suggests the transformer is running close to its maximum load. Adding more filter capacitance is not a good thing to do, as it increases the resistive losses in the transformer windings.