Audio Asylum Thread Printer Get a view of an entire thread on one page |
For Sale Ads |
149.88.21.139
In Reply to: RE: AudioNote UK 4242E moly plate 211 - plates are pink (!!) posted by deafbykhorns on June 11, 2025 at 11:30:29
Still haven't heard back after a few emails over to Cary....
Bias for the 300B says 60mA DC in the manual. With the stock 211 tube:
WE300B - 56.7mA
Stock Genelex 300B - 61.5mA
Didn't change anything besides swapping out the WE300B.
Both measured with an external meter with the 1/4" jack in the back of the amp. So am not far off with both 300B.
The amps can use either 211 or 845 with a switch. Any advice what would happen if wired incorrectly with the 211 running on 845 settings?
Just wondering, thanks.
![]()
![]()
"211 running on 845 settings"
A 211 running at 845 bias would pass very little current.
A 845 at 211 bias would be red platting.
Tre'
Have Fun and Enjoy the Music
"Still Working the Problem"
Thanks Tre'. At least that is not the problem.
Still no reply from Cary, and so am a bit frustrated.I'm not certain the amps are still under warranty, but to have to crate them up and ship them back to Cary will be a big deal as they are very heavy and bulky.
I will call them to see if there is an authorized service place closer to me.
For others possibly reading this thread, please advise if you know of a skilled tech in the greater NY metro - I'll probably need to start a new thread to ask.... Thank you in advance!
Edits: 06/16/25