Home Tweakers' Asylum

Tweaks for systems, rooms and Do It Yourself (DIY) help. FAQ.

OVERHEATING OF OP AMPS ... HELP!!!!

80.58.33.42

I HAVE INSTALLED A NEW OP AMP (AD826AN) IN THE ANALOG SECTION OF MY ARCAM CD72T CD PLAYER TO REPLACE THE STANDARD UNITS (JRC2114D), AND I HAVE OBSERVED THAT THEY RUN VERY, VERY HOT FROM THE START.

I HAVE CHANGED TO ANOTHER OP AMP (OPA2604)AND THE SAME OCCURS.

THE VOLTAGE OF THE SUPLY RAILS IS +/-12V.

THE OP AMPS ARE BYPASSED BY EVOX 100pF CERAMIC CAPACITORS.

THE INTERCONNECT CABLE IS VDH THE FIRST ULTIMATE.

THE ANALOG SECTION OF THE CD PLAYER (ACCORDING TO A REVIEW OF WHAT HI*FI MAGAZINE) RUNS IN CLASS A.

WHAT IS HAPPENING?
ARE THE OP AMPS OSCILLATING?
WHAT CAN I DO?

I CAN SEND PICTURES OF THE ANALOG SECTION SHOWING HOW IS ALL CONNECTED.

THANKS IN ADVANCE FOR ANY HELP.

THE INTERCONNECT CABLE IS VDH THE FIRST ULTIMATE.


This post is made possible by the generous support of people like you and our sponsors:
  VH Audio  


Topic - OVERHEATING OF OP AMPS ... HELP!!!! - langel 14:26:50 03/21/04 (13)