In Reply to: Re: They are 2ml samples, but a little goes a long way. posted by John A on September 17, 2000 at 14:18:20:
Be VERY careful using CAIG products on tube pins, particularly 9 pin minis or any tube where the glass meets the pins directly. CAIG products can cause the pins to slightly shrink, due to removal of a very microscopic layer of metal, and will penetrate the seal at the pins, if you clean the tube pins and then put the tubes aside for future use, you will sometimes find that the seal has been penetrated, perhaps even to the extent of causing a crack in the glass...the getter has turned to white powder...vacuum gone, even from a microscopic leak...tube dead but pins really clean, very bad day.
This post is made possible by the generous support of people like you and our sponsors:
Follow Ups
- WARNING! - robert 11:54:40 09/18/00 (3)
- Re: WARNING! - John A 18:50:18 09/18/00 (2)
- Re: WARNING! - robert 07:12:27 09/19/00 (1)
- Re: WARNING! - John A 07:18:45 09/19/00 (0)