In Reply to: Hickok 6000 Basic Tube Testing posted by srivenkat on February 15, 2010 at 18:25:02:
Hi Sri,
The Quality Test is a preliminary good/bad test. To perform this test set the shunt dial to the number given on the roll chart. This test is not meant to give you a micromhos reading.
If you want to know the micromhos readings, set the shunt dial to the appropriate red dot. So if the average new reading on the roll chart is less than 3000 set it to the dot near 73 on the shunt dial and so on.
Hope this helps, let me know if you have additional questions.